02/24/21
Message Overview:
Message Description:
Used for blocking faults lower priority faults when aircraft is using a SRT 2000. Equation will set if label 357 is present but will not set for SRT 2200. This equation will allow equations with priority lower than this equation to still run on the SRT 2200.
Possible Causes:
- SATCOM Transceiver (A82)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 16
- Comp Id = A082
- Fault Logged = NEVER
- Status = DON'T FAIL
- {Term Definitions}
- SRT1-3 XX 357 NA ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 357: (A) NO IOC XX IN; SRT 2200 O
Quick Links:
| Removal of the SATCOM Satellite Data Unit (SDU) | AMM 23-15-01-000-801 |
| Installation of the SATCOM Satellite Data Unit (SDU) | AMM 23-15-01-400-801 |
| Removal of the SATCOM Satellite Data Unit (SDU) mounting tray | AMM 23-15-05-000-801 |
| Installation of the SATCOM Satellite Data Unit (SDU) mounting tray | AMM 23-15-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Used for blocking faults lower priority faults when aircraft is using a SRT 2000. Equation will set if label 357 is present but will not set for SRT 2200. This equation will allow equations with priority lower than this equation to still run on the SRT 2200.