Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/24/21

Message Overview:

Message Name:

NO L-IOC-2 BUS INPUT

Message Code:

B3-666827

Associated CAS:

None

Reporting LRU: SAT 2X00
System Description: 23-00-00
Schematic Diagram: 23-15-00 (POST SB 350-23-012)
23-15-00 (POST SB 350-23-013)
Wiring Diagram: 23-15-09

Message Description:

L-IOC-2 bus is reported missing by SATCOM but is not reported failed by 3 of [L-FSU, WXR RTA, L-TDR and (TSS or R-TDR)].

Possible Causes:

  • SATCOM Satellite Data Unit (SDU)
  • Junction Box (JB4)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the SATCOM Satellite Data Unit (SDU) AMM 23-15-01-000-801
Installation of the SATCOM Satellite Data Unit (SDU) AMM 23-15-01-400-801
Removal of the Junction Box (JB4) AMM 24-63-13-000-802
Installation of the Junction Box (JB4) AMM 24-63-13-400-802
Removal of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-000-801
Installation of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-400-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Wire Repair SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Reset SATCOM (CB4-D2) circuit breaker.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Do wiring check of ARINC 429 data bus L-IOC-2 from IAPS connector A4P3, through Junction Box 4, to SDU connector A82BP1. Repair/replace as required.

    1. If system check passes, do close out.
    2. If fault remains, continue with next step.

  3. Replace SDU.