Message Overview:
Message Description:
Internal fault to the FIREX Control Unit has been detected.
Possible Causes:
- FIREX Control Unit (A91)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
During aircraft power-up, if the aircraft left essential bus (L BATT) is depressed first, the right essential bus (R BATT) will power up approximately 700 milliseconds later. This threshold value may be close enough to upset the FIREX control unit microprocessor delay time to monitoring the discrete. The microprocessor is being fed from the left essential bus, whereas the output discretes circuits are being powered from the right essential bus.
Quick Links:
| Removal of the Fire-Detection-and-Extinguishing (FIREX) Control-Unit | AMM 26-11-01-000-801 |
| Installation of the Fire-Detection-and-Extinguishing (FIREX) Control-Unit | AMM 26-11-01-400-801 |
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check and reset FIREX Control Unit (A91) circuit breaker CB5-A3, CB6-A4 in DCPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Check and reset Fire Detector circuit breakers CB2-A11 (R BATT) and then CB1-A11 (L BATT).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring check between FIREX control unit and circuit breakers and ground. (repair as required).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FIREX control unit.
- Do close out.