02/26/21
Message Overview:
Message Description:
Internal fault detected by ISI.
Possible Causes:
- Integrated Standby Instrument (ISI) (A90)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Standby Instrument | AMM 34-12-01-000-801 |
| Installation of the Integrated Standby Instrument | AMM 34-12-01-400-801 |
| Functional Test of the Integrated Standby Instrument | AMM 34-12-01-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- In Maintenance Main Menu, select LRU INDEX/OPERATIONS and check ISI Label 350.
- If ISI label 350 bit 27 is set to 0 (ISI Powered), go to step 5.
- If ISI label 350 bit 27 is set to 1 (ISI Not Powered), continue with next step.
- Ensure STBY INST circuit breaker CB2-C6 is pushed in.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- On pedestal, cycle the STBY INST Battery switch from OFF position to ON. Ensure OFF PBA is off.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Verify ISI power 28 VDC is present on pin D of A90P1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace ISI.
- Do close out.