03/01/21
Message Overview:
Message Description:
No L-ADC-1 input through IOC 1 to SECU 1.
Possible Causes:
- Air Data Computer 1 (ADC 1) (A1)
- Spoiler Electronic-Control Unit 1 (SECU 1) (A118)
- Input/Output Concentrator (IOC 1) (A4-IOC1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-000-801 |
| Installation of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-400-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-802 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
| Removal of the Air Data Computer | AMM 34-13-01-000-801 |
| Installation of the Air Data Computer | AMM 34-13-01-400-801 |
| Functional Test of the Air Data Computer | AMM 34-13-01-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Swap ADCs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SECUs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: Spoiler system must be rigged after SECU replacement.
- Swap IOCs.
- Do close out.