03/02/21
Message Overview:
Message Description:
Program Pin Fault detected by Spoiler Electronics Control Unit 2 (SECU 2).
Possible Causes:
- Spoiler Electronic-Control Unit 2 (SECU) (A119)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-000-801 |
| Installation of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-400-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Ring out the SECU wiring and verify the program pin operation.
- If the fault still exists, swap the SECUs per AMM TASK 27-61-05-000-801, (Spoiler system must be rigged after SECU replacement, AMM TASK 27-61-05-820-802).