03/03/21
Message Overview:
Message Name:
DISCRETE INPUT TO DCU
(Service Message)
Message Code:
B3-008110
Associated CAS:
| Reporting LRU: | WING A/ICE VLV 1 |
| System Description: | 30-00-00 |
| Schematic Diagram: | None |
| Wiring Diagram: | None |
Message Description:
A disagreement has been detected between the position feedback from the WING ANTI-ICE VALVE 1 to the Data Concentrator Unit and the WING PBA selection feedback to the Data Concentrator Unit.
Possible Causes:
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 4
- {Term Definitions}
- DWDC1-18 1X 111 00 EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 111A: 14;WING A/I SELECTED OFF B
- DWDC1-7 1X 106 00 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 106A: 15;L WAIV OPEN
Quick Links:
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do a wiring check?