03/04/21
Message Overview:
Message Description:
The hardwired LOW TEMPERATURE 2 DISCRETE output to the Data Concentrator Unit is detected failed.
Possible Causes:
- Integrated Air System Controller 2 (IASC) (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 1
- {Term Definitions}
- IAS2A-68 XX 353 11 EXCT XXXX-XXXX XXXX-XXXX XXXX-TXXX 353B:12; LOW TEMP HW DISCRETE 2
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Integrated Air System (IAS) Controller | AMM 21-31-01-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Check wiring.