Message Overview:
Message Description:
Data Concentrator Unit (DCU) Channel A has an invalid configuration.
Possible Causes:
- Data Concentrator Unit (DCU) (A14)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset EICAS DCU A Circuit Breaker CB1-D1 and EICAS DCU B Circuit Breaker CB2-D1. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Confirm the configuration strapping of the DCU.
Measurement at Expected Result Result Conn. A14CP1 - 7B Aircraft Ground Conn. A14CP1 - 8K Aircraft Ground Conn. A14CP1 - 7A Aircraft Ground Conn. A14CP1 - 7K Aircraft Ground - If the check is satisfactory, replace defective DCU (A14).
- If the check is not satisfactory, repair wiring.
- Do close out.