background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/05/25

Message Overview:

Message Name:

NO A-RDC-1 BUS INPUT

Message Code:

B3-006516

Reporting LRU: Data Concentrator Unit (DCU) Channel A
Associated CAS: None
System Description: 31-41-00 - Engine Indication and Crew Alerting System (EICAS)
Schematic Diagram: SSM 31-41-00-101 - Engine Indication and Crew Alerting System (EICAS)
Wiring Diagram: WM 31-41-11-1_001 - Sheet 1 - Remote Data Concentrator (Interface) - ALL
WM 31-41-13-1_001 - Sheet 1 - EICAS (Power and Indication) - ALL

Message Description:

A-RDC-1 bus is reported inoperative by Data Concentrator Unit (DCU) Channel A, while A-RDC-1 bus is not reported inoperative by DCU Channel B.

Possible Causes:

  • Data Concentrator Unit (DCU) (A14)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

Quick Links:

Removal of the Data Concentrator Unit (DCU) AMM 31-41-01-000-802
Installation of the Data Concentrator Unit (DCU) AMM 31-41-01-400-802
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Reset EICAS DCU A Circuit Breaker CB1-D1. Is the fault message still present?
    1. If NO, do close out.
    2. If YES, continue with next step.

  2. Replace DCU (A14).
  3. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.