Message Overview:
Message Description:
PSEU detects an overload condition on the discrete output to the Right Attitude Heading Reference Computer (RAHRC). Verify user interface to RAHRC A012 and related wiring.
Possible Causes:
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Right Attitude Heading Computer (AHC) (A12)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the AHRC connector A12P1 Pin 122 to the PSEU connector A9AP1 Pin 1J. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the AHRC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.