03/10/21
Message Overview:
Message Description:
PSEU detects an overload on the discrete output to the Stall Protection Computer (SPC) Channel A. Verify user interface, SPC-A A178 and related wiring.
Possible Causes:
- Stall Protection Computer (SPC) (A178)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Stall Protection System (SPS) | AMM 27-32-00-710-801 |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the SPC connector A178AP1 Pin 28 to the PSEU connector A9AP1 Pin 5J. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the SPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.