Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the Completion Center Relay (CCR)-K50.
Possible Causes:
- CCR-K50 (Junction Box 4 - Circuit Card 2)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 Circuit-Cards | AMM 24-63-13-000-803 |
| Installation of the Junction Box JB4 Circuit-Cards | AMM 24-63-13-400-803 |
| Operational Test of Junction Box JB4 Card 2 | AMM 24-63-13-710-802 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the JB4-DB2 connector JB4EP1 Pin 19 to the PSEU connector A9CP1 Pin 10A. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Circuit Board 2 of the Junction Box 4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.