Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the Left DC Power Computer (DCPC).
Possible Causes:
- L GEN GCU PCB PCB5 (Left DCPC A35)
- PROT PCB PCB1 (Left DCPC A35)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Energize the Primary DC-Power Supply | AMM 24-31-00-861-801 |
| Operational Test of the Main Generator | AMM 24-31-05-710-801 |
| Removal of the Generator Control Unit (GCU) - Primary | AMM 24-31-13-000-801 |
| Installation of the Generator Control Unit (GCU) - primary | AMM 24-31-13-400-801 |
| Removal of the DC Power-Center Protection | AMM 24-61-77-000-801 |
| Installation of the DC Power-Center Protection | AMM 24-61-77-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the LDCPC connector A35P2 Pin u to the PSEU connector A9CP1 Pin 9D. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the L GEN GCU PCB PCB5.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PROT PCB PCB1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.