Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the Clock.
Possible Causes:
- Clock (A121)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Digital Clock | AMM 31-21-01-000-801 |
| Installation of the Digital Clock | AMM 31-21-01-400-801 |
| Operational Test of the Digital Clock | AMM 31-21-01-710-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Do wiring check from the Clock (A121) connector A121P1 Pin A to the PSEU connector A9CP1 Pin 9C. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Clock.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.