03/10/21
Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the Cockpit Voice Recorder (CVR) Erase Enable Relay, K40.
Possible Causes:
- Cockpit Voice Recorder (CVR) Relay (K40)
- Junction Box JB4 Circuit-Card 4 (JB4-DB4)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB2 Circuit-Cards | AMM 24-63-05-000-802 |
| Installation of the Junction Box JB2 Circuit-Cards | AMM 24-63-05-400-802 |
| Operational Test of Junction Box JB2 Card 4 | AMM 24-63-05-710-829 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| IInstallation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring checks from the JB2-DB4 connector JB2BP1 Pin 26 to the PSEU connector A9AP1 Pin 2K. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Circuit Board 4 of the Junction Box #2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.