Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the Light Panel PL13.
Possible Causes:
- Lighting Control Panel (PL13)
- Relay (K15)
- Proximity-Sensor Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Removal of the LIGHTING Control Panel | AMM 33-41-01-000-801 |
| Installation of the LIGHTING Control Panel | AMM 33-41-01-400-801 |
| Operational Test of the External Lights | AMM 33-40-00-710-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the Lighting Panel connector PL13P2 Pin 34 to the PSEU connector A9AP1 Pin 3K. Repair as required.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Do wiring check from the Lighting Panel connector PL13P2 Pin 35 to the Right Secondary Power Center connector A38P3 Pin 5. Repair as required.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace the Lighting Panel.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace the Nose Taxi Relay K15.
- If system checks are good, do close out.
- If fault remains continue with next step.
- Replace the PSEU.
- Do close out.