03/10/21
Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects an overload condition on the discrete output to the Completion Center Relay (CCR) K51.
Possible Causes:
- Junction Box 4 (JB4) Circuit-Card 2 (JB4-DB2)
- Completion Center Relay (CCR) (K51)
- Proximity Sensor-Electronic Unit (PSEU) (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB2 Circuit-Cards | AMM 24-63-05-000-802 |
| Installation of the Junction Box JB2 Circuit-Cards | AMM 24-63-05-400-802 |
| Operational Test of Junction Box JB4 Card 2 | AMM 24-63-13-710-802 |
| Removal of the Proximity−Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity−Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity−Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the JB4-DB2 connector JB4EP1 Pin 20 to the PSEU connector A9AP1 Pin 1K. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Circuit Board 2 of the Junction Box 4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.