Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects that the discrete output to the Power Transfer Unit (PTU) is not connected to the user interface.
Possible Causes:
- Hydraulic Control Panel (PL11)
- Power Transfer Unit (PTU) Select Valve (MT115)
- Proximity Sensor-Electronic Unit (A9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the HYDRAULIC Control Panel | AMM 29-11-01-000-801 |
| Installation of the HYDRAULIC Control Panel | AMM 29-11-01-400-801 |
| Operational Test of the HYDRAULIC Control Panel | AMM 29-11-01-710-801 |
| Functional Test of the Power Transfer Unit (PTU) | AMM 29-12-57-720-801 |
| Removal of the PTU Solenoid | AMM 29-12-61-000-801 |
| Installation of the PTU Solenoid | AMM 29-12-61-400-801 |
| Removal of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-000-801 |
| Installation of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check from the Hydraulic Control Panel connector PL11P2 Pin 20 to the PSEU connector A9AP1 Pin 7K. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check from the Hydraulic Control Panel connector PL11P2 Pin 20 to the PTU Solenoid connector MT115P1 Pin B. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the Hydraulic Control Panel.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PTU Solenoid MT115.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the PSEU.
- Do close out.