Message Overview:
Message Description:
Proximity Sensor Electronic Unit detects that the right gear was in transit between Uplock and Downlock for more than 28 seconds. Verify rigging/status.
Possible Causes:
- Main Landing-Gear Uplock Proximity-Sensor (RH) (PX04)
- Main Landing-Gear Downlock 1 Proximity-Sensor (RH) (PX08)
- Main Landing-Gear Downlock 2 Proximity-Sensor (RH) (PX38)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Adjustment of the Proximity Sensors | AMM 32-61-00-820-801 |
| Removal of the Main Landing-Gear (MLG) Proximity-Sensors | AMM 32-61-01-000-801 |
| Installation of the Main Landing-Gear (MLG) Proximity-Sensors | AMM 32-61-01-400-801 |
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do the rigging with the adjustment of the sensor PX08.
- If the rigging is good, go to step 4.
- If fault remains, continue with next step.
- Replace the sensor PX08.
- Go to step 1.
- Do the rigging with the adjustment of the sensor PX38.
- If the rigging is good, go to step 7.
- If fault remains, continue with next step.
- Replace the sensor PX38.
- Go to step 4.
- Do the rigging with the adjustment of the sensor PX04.
- If the rigging is good, do close out.
- If fault remains, continue with next step.
- Replace the sensor PX04.
- Go to step 7.
- Do close out.