Message Overview:
Message Description:
No R-ADC data received at the R-IOC and 3-of (AHC2, MFD2, PFD2, MFD1, PFD1, SPC-B).
Possible Causes:
- Right Air Data Computer (ADC) (A2)
- Reversion Select Panel (PL27)
- Relay (K130)
- Right Secondary Power Center (SPC) (A38)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary Power Center (SPC) | AMM 24-62-01-000-801 |
| Installation of the Secondary Power Center (SPC) | AMM 24-62-01-400-801 |
| Removal of the Secondary Power Center (SPC) Relays | AMM 24-62-04-000-801 |
| Installation of the Secondary Power Center (SPC) Relays | AMM 24-62-04-400-801 |
| Removal of the Reversion Select Panel | AMM 31-61-13-000-801 |
| Installation of the Reversion Select Panel | AMM 31-61-13-400-801 |
| Removal of the Air Data Computer | AMM 34-13-01-000-801 |
| Installation of the Air Data Computer | AMM 34-13-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset AIR DATA 2 (CB2-C1) circuit breaker. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Confirm AIR DATA Switch (Reversion Select Panel) and Relay K130 (Right Secondary Power Center) are operating as per drawing [presence of 28 VDC / Grounds at Right ADC connector A2P1].
- If wiring defects are found, repair defective wiring as required and do close out.
- If no wiring defects are found, continue with next step.
- Remove and re-rack the right ADC, making sure it is fully and properly inserted into place. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace the right ADC.
- Do close out.