03/18/21
Message Overview:
Message Description:
PREREQUISITE
Possible Causes:
- RH Control Display Unit (CDU) (Installation with Dual CDUs) (A68)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = CDU1 CDU 1
- ATA Chapter = 34-61
- Comp Id = A068
- Fault Logged = AIR
- {Term Definitions}
- OPT1-31 XX 360 NA EXCT CSU WD-04 XXXX-XXXX XXXX-XFFT 9,10,11: 1 FMC/1 CDU STR
- OPT1-32 XX 360 NA EXCT CSU WD-04 XXXX-XXXX XXXX-XFTF 9,10,11: 1 FMC/2 CDU STR
- OPT1-33 XX 360 NA EXCT CSU WD-04 XXXX-XXXX XXXX-XFTT 9,10,11: 2 FMC/2 CDU STR
- OPT1-34 XX 360 NA EXCT CSU WD-04 XXXX-XXXX XXXX-XTTF 9,10,11: 3 FMC/3 CDU STR
Quick Links:
| Removal of the Control Display Unit (CDU) | AMM 34-61-05-000-801 |
| Installation of the Control Display Unit (CDU) | AMM 34-61-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- None