07/18/19
Message Overview:
Message Description:
CDU1 is reporting R-GP-1 bus inactive, while at least 2 of the following are reporting R-GP-1 active; CDU2, ADC2, RIU2.
Possible Causes:
- Control Display Unit (CDU) (A68)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = CDU1 CDU 1
- ATA Chapter = 34-61
- Message# = 14
- Comp Id = A068
- {Term Definitions}
- CDU1-4 1X 350 01 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13;NO R-GP-1 IN
- CDU2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13;NO R-GP-1 BUS INPUT
- RIU2-26 2X 351 10 EXCT XXXX-XXXX XXXX-TXXX XXXX-XXXX 351: 20;R-GPBUS INACTIVE
- ADC2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 350: 15;NO R-GP-1 IN
Quick Links:
| Removal of the Control Display Unit (CDU) | AMM 34-61-05-000-801 |
| Installation of the Control Display Unit (CDU) | AMM 34-61-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Suspect wiring or the CDU.
- Do close out.