03/19/21
Message Overview:
Message Description:
CDU1 is reporting LB-RIU-6 bus inactive, while at least 2 of the following are reporting LB-RIU-6 active; DCU1, MFD1, PFD1.
Possible Causes:
- Control Display Unit (CDU) (A68)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = CDU1 CDU 1
- ATA Chapter = 34-61
- Message# = 15
- Comp Id = A068
- {Term Definitions}
- CDU1-7 1X 350 01 EXCT XXXX-XXXX XXXX-XXXX TXXX-XXXX 350: 16;NO LB-RIU-6 I
- DCU1-28 1X 357 01 EXCT XXXX-XXXX TXXX-XXXX XXXX-XXXX 357: 24;LB-RIU-6 BUS INOP
- PFD1-35 1X 351 NA EXCT XXXX-XTXX XXXX-XXXX XXXX-XXXX 351: 27;NO LB-RIU-6 INPUT
- MFD1-35 1X 351 NA EXCT XXXX-XTXX XXXX-XXXX XXXX-XXXX 351: 27;NO LB-RIU-6 INPUT
Quick Links:
| Removal of the Control Display Unit (CDU) | AMM 34-61-05-000-801 |
| Installation of the Control Display Unit (CDU) | AMM 34-61-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Suspect wiring, or the CDU.
- Do close out.