03/19/21
Message Overview:
Message Description:
CDU1 is reporting RB-RIU-9 bus inactive, while MFD1 and PFD1 are reporting RB-RIU-9 bus active.
Possible Causes:
- Control Display Unit (CDU) (A68)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = CDU1 CDU 1
- ATA Chapter = 34-61
- Message# = 16
- Comp Id = A068
- {Term Definitions}
- CDU1-6 1X 350 01 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 350: 15;NO RB-RIU-9 I
- PFD1-36 1X 351 NA EXCT XXXX-TXXX XXXX-XXXX XXXX-XXXX 351: 28;NO RB-RIU-9 INPUT
- MFD1-36 1X 351 NA EXCT XXXX-TXXX XXXX-XXXX XXXX-XXXX 351: 28;NO RB-RIU-9 INPUT
Quick Links:
| Removal of the Control Display Unit (CDU) | AMM 34-61-05-000-801 |
| Installation of the Control Display Unit (CDU) | AMM 34-61-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Suspect wiring, or the CDU.
- Do close out.