03/19/21
Message Overview:
Message Description:
CDU2 is reporting R-GP-1 bus inactive, while at least 2 of the following are reporting R-GP-1 active; CDU1, ADC2, RIU2.
Possible Causes:
- Control Display Unit (CDU) (A69)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- LRU = CDU2 CDU 2
- ATA Chapter = 34-61
- Message# = 13
- Comp Id = A069
- {Term Definitions}
- CDU2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13;NO R-GP-1 BUS INPUT
- IOC2-1 2X 350 10 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 350: (A) NO IOC 2X IN;
- CDU1-4 1X 350 01 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13;NO R-GP-1 IN
- ADC2-4 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 350: 15;NO R-GP-1 IN
- RIU2-26 2X 351 10 EXCT XXXX-XXXX XXXX-TXXX XXXX-XXXX 351: 20;R-GPBUS INACTIVE
Quick Links:
| Removal of the Control Display Unit (CDU) | AMM 34-61-05-000-801 |
| Installation of the Control Display Unit (CDU) | AMM 34-61-05-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Suspect wiring or the CDU.