03/22/21
Message Overview:
Message Description:
An internal fault is detected with IRU 1.
Possible Causes:
- Internal Reference Unit (IRU) No. 1 (A233)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Inertial Reference Unit (IRU) | AMM 31-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 31-45-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset IRS 1 (CB1-C2) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace IRU 1.
- Do close out.