Message Overview:
Message Description:
LDS-1 data bus is absent at least 2 of (L-PFD, L-MFD, R-PFD, R-MFD).
Possible Causes:
- Adaptive Flight-Display Unit PFD2 (A26)
- Adaptive Flight-Display Unit PFD1 (A27)
- Adaptive Flight-Display Unit MFD2 (A28)
- Adaptive Flight-Display Unit MFD1 ( A29)
- Lightning Detection Processor (LDU) (A77)
- Junction Box 1 (JB1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Removal of the Lightning Detection Processor | AMM 34-46-01-000-801 |
| Installation of the Lightning Detection Processor | AMM 34-46-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset Lighting DET Circuit Breaker CB3-E3. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between LDU (A77), through JB1, to the 4 Adaptive Display Unit (A26, A27, A28, and A29) for the following wires:
From To Result Conn. A77P2 - 38 Conn. A26P2 - 86 Conn. A77P2 - 21 Conn. A26P2 - 87 Conn. A77P2 - 38 Conn. A27P2 - 86 Conn. A77P2 - 21 Conn. A27P2 - 87 Conn. A77P2 - 38 Conn. A28P2 - 86 Conn. A77P2 - 21 Conn. A28P2 - 87 Conn. A77P2 - 38 Conn. A29P2 - 86 Conn. A77P2 - 21 Conn. A29P2 - 87 - If check is satisfactory, continue with next step.
- If check is not satisfactory, repair defective wiring or replace JB1.
- Disconnect L PFD. Is the fault message still present?
- If NO, replace defective Adaptive Display Unit.
- If YES, continue with next step.
NOTE: An internal short circuit of the ARINC receiver could result in a transmission failure for the LDS-1 data bus.
- Disconnect L MFD. Is the fault message is still present?
- If NO, replace defective Adaptive Display Unit.
- If YES, continue with next step.
NOTE: An internal short circuit of the ARINC receiver could result in a transmission failure for the LDS-1 data bus. - Disconnect R MFD. Is the fault message is still present?
- If NO, replace defective Adaptive Display Unit.
- If YES, continue with next step.
NOTE: An internal short circuit of the ARINC receiver could result in a transmission failure for the LDS-1 data bus.
- Disconnect R PFD. Is the fault message is still present?
- If NO, replace defective Adaptive Display Unit.
- If YES, continue with next step.
NOTE: An internal short circuit of the ARINC receiver could result in a transmission failure for the LDS-1 data bus.
- Replace LDU (A77).
- Do close out.