Message Overview:
Message Description:
Lighting Detection Processor has reported an internal failure or an antenna failure.
Possible Causes:
- Lightning Detection Processor (LDU) (A77)
- Lightning Detection Antenna (E23)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Lightning Detection Processor | AMM 34-46-01-000-801 |
| Installation of the Lightning Detection Processor | AMM 34-46-01-400-801 |
| Removal of the Lightning Detection Antenna | AMM 34-46-09-000-801 |
| Installation of the Lightning Detection Antenna | AMM 34-46-09-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset Lighting DET Circuit Breaker CB3-E3. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between LDU (A77) and the Lighting detection Antenna (E23) for the following wires:
From To Result Conn. A77P1 - 17 Conn. E23P1 - G Conn. A77P1 - 33 Conn. E23P1 - H Conn. A77P1 - 49 Conn. E23P1 - M Conn. A77P1 - 50 Conn. E23P1 - L Conn. A77P1 - 15 Conn. E23P1 - E Conn. A77P1 - 48 Conn. E23P1 - F Conn. A77P1 - 45 Conn. E23P1 - B Conn. A77P1 - 24 Conn. E23P1 - C Conn. A77P1 - 14 Conn. E23P1 - D Conn. A77P1 - 30 Conn. E23P1 - A Conn. A77P1 - 47 Conn. E23P1 - J - If check is satisfactory, continue with next step.
- If check is not satisfactory, repair defective wiring.
- Replace LDU (A77). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the Lighting Detection Antenna (E23).
- Do close out.