03/25/21
Message Overview:
Message Description:
RALT-2 bus data absent at R-IOC.
Possible Causes:
- Radio Altimeter Transceiver (RAD ALT 4000) (A32)
- Input/Output Concentrator Unit 1 (IOC) (A4-IOC1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 5
- {Term Definitions}
- RALT1-2 2X 350 01 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 350: (A) NO IOC 2X IN;
- IOC2-1 2X 350 10 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 350: (A) NO IOC 2X IN;
Quick Links:
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Radio Altimeter Transceiver | AMM 34-44-01-000-801 |
| Installation of the Radio Altimeter Transceiver | AMM 34-44-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Suspect failed RALT-2 output, wiring, or failed R-IOC.