background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/25/21

Message Overview:

Message Name:

NO RALT-2 BUS OUTPUT

Message Code:

B3-007672

Associated CAS:

None

Reporting LRU: RAD ALT 4000
System Description: 34-44-00
Schematic Diagram: 34-44-00
Wiring Diagram: 34-44-01

Message Description:

RALT-2 bus data absent at R-IOC.

Possible Causes:

  • Radio Altimeter Transceiver (RAD ALT 4000) (A32)
  • Input/Output Concentrator Unit 1 (IOC) (A4-IOC1)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure:

  1. Message# = 5
  2. {Term Definitions}

    1. RALT1-2 2X 350 01 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 350: (A) NO IOC 2X IN;
    2. IOC2-1 2X 350 10 ABSN XXXX-XXXX XXXX-XXXX XXXX-XXXX 350: (A) NO IOC 2X IN;

Quick Links:

Removal of the Input/Output Concentrator Unit (IOC) AMM 31-45-05-000-801
Installation of the Input/Output Concentrator Unit (IOC) AMM 31-45-05-400-801
Removal of the Radio Altimeter Transceiver AMM 34-44-01-000-801
Installation of the Radio Altimeter Transceiver AMM 34-44-01-400-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Repair Wiring SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Suspect failed RALT-2 output, wiring, or failed R-IOC.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.