03/25/21
Message Overview:
Message Description:
Internal failure indicated in TAWS. The ARINC Word with a bit set will help analyze internal problem. Internal fault will set when any of these bits set. Bits 19-29 in 351 label or bits 11-15 in 355 label.
Possible Causes:
- Terrain-Avoidance Warning System (TAWS) Computer (A34)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- Comp Id = A034
- {Term Definitions}
- TAWS1-9 XX 351 00 OR'D XXXT-TTTT TTTT-TTXX XXXX-XXXX 351: 19-29; MISC FAIL CONDITIONS
- TAWS1-10 XX 355 00 OR'D XXXX-XXXX XXXX-XXXX XTTT-TTXX 355: 15&14&13&12&11;INT FAULTS
Quick Links:
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Terrain-Avoidance Warning System (TAWS) Computer | AMM 34-42-01-000-802 |
| Installation of the Terrain-Avoidance Warning System (TAWS) Computer | AMM 34-42-01-400-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Internal failure indicated in TAWS. The ARINC Word with a Bit set will help analyze internal problem. Internal fault will set when any of these bits set. Bits 19-29 in 351 label or bits 11-15 in 355 label.
- Replace TAWS.