03/25/21
Message Overview:
Message Description:
Internal fault to the right TDR has occurred.
Possible Causes:
- Right Air Traffic Control (ATC) Transponder (TDR) (A30)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- Comp Id = A030
- {Term Definitions}
- TDR2-6 2X 350 10 EXCT XXXX-XXXX FFFT-XXXX XXXX-XXXX 350: (1X);POWER SUPPLY
- TDR2-10 2X 350 10 EXCT XXXX-XXXX FTFT-XXXX XXXX-XXXX 350: (5X);ROM
- TDR2-11 2X 350 10 EXCT XXXX-XXXX FTTF-XXXX XXXX-XXXX 350: (6X);RAM
- TDR2-12 2X 350 10 EXCT XXXX-XXXX TFTT-FFFT XXXX-XXXX 350: (B1);TCAS UART FAIL
- TDR2-16 2X 350 10 EXCT XXXX-XXXX TTFF-XXXX XXXX-XXXX 350: (CX);SQUITTER FAIL
- TDR2-17 2X 350 10 EXCT XXXX-XXXX TTFT-XXXX XXXX-XXXX 350: (DX);DIVERSITY FAIL
- TDR2-18 2X 350 10 EXCT XXXX-XXXX TTTF-FFTT XXXX-XXXX 350: (E3);PROCESSOR FAIL
- TDR2-19 2X 350 10 EXCT XXXX-XXXX TTTF-FTFF XXXX-XXXX 350: (E4);PROCESSOR FAIL
Quick Links:
| Removal of the Air Traffic Control (ATC) Transponder | AMM 34-54-01-000-801 |
| Installation of the Air Traffic Control (ATC) Transponder | AMM 34-54-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Right TDR requires replacement or troubleshooting.