03/26/21
Message Overview:
Message Description:
TAT Probe has failed.
Possible Causes:
- Total Air Temperature (TAT) Probe (RH) (A16)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 1
- Comp Id = A016
- {Term Definitions}
- ADC1-3 1X 350 01 OR'D XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13;TEMP PROBE I/O
- ADC2-3 2X 350 10 EXCT XXXX-XXXX XXXX-XXXX XXXT-XXXX 350: 13;TEMP PROBE I/O
Quick Links:
| Removal of the Total Air Temperature (TAT) Probe | AMM 34-11-13-000-801 |
| Installation of the Total Air Temperature (TAT) Probe | AMM 34-11-13-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Replace TAT Probe.
- Do close out.