03/31/21
Message Overview:
Message Description:
Set when a received data error is detected on any of the DBU input buses.
Possible Causes:
- Data Base Unit 1 (DBU) (A191)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- {Term Definitions}
- DBU1-2 2X 351 00 EXCT XXXX-XXXX XXXX-XXXX XTXX-XXXX 351 :15;RECVD DATA FAULT
Quick Links:
| Removal of the Data Loader Panel | AMM 25-72-03-000-801 |
| Installation of the Data Loader Panel | AMM 25-72-03-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Set when a received data error is detected on any of the DBU input buses. Suspect the DBU.