03/31/21
Message Overview:
Message Description:
TSS is reporting an internal failure.
Possible Causes:
- Traffic Alert And Collision-Avoidance System (TCAS) Transceiver (TSS-4100) (A238)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit | AMM 34-43-03-000-801 |
| Installation of the Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit | AMM 34-43-03-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset TCAS/XPDR1 Circuit Breaker CB1-A5. Is the fault message still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder Unit (A238).
- Do close out.