04/01/21
Message Overview:
Message Description:
No TAWS data received at 3-of (L-IOC, R-IOC, L-PFD, L-MFD, R-PFD, R-MFD).
Possible Causes:
- Terrain-Avoidance Warning System (TAWS) Computer (A34)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Terrain-Avoidance Warning System (TAWS) Computer | AMM 34-42-01-000-801 |
| Installation of the Terrain-Avoidance Warning System (TAWS) Computer | AMM 34-42-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset TAWS (CB2-A6) circuit breaker or push the TAWS TEST/RESET Switch on the center pedestal.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Confirm presence of the 28 VDC and Grounds at the TAWS computer connector A34CP1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace the TAWS computer.
- Do close out.