04/05/21
Message Overview:
Message Description:
R-IOC-4 data absent at L-FMC. R-IOC-4 data is not missing at R-FMC and SVC.
Possible Causes:
- Left Flight Management Computer (FMC) (A4-FMC1)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Flight Management Computer (FMC) | AMM 34-61-01-000-801 |
| Installation of the Flight Management Computer (FMC) | AMM 34-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset L IAPS (CB1-B6) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace FMC 1.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace IAPS Card Cage (ICC).
- Do close out.