04/06/21
Message Overview:
Message Description:
No R-IRS-4 data is received at SVC but is not reported failed at SATCOM.
Possible Causes:
- Synthetic Vision Computer (SVC) (A230)
- Junction Box (JB2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: A GPS signal input is required for the SVS image to show on the pilot and the co-pilot primary flight display (PFD).
Quick Links:
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Synthetic Vision Computer (SVC) | AMM 34-34-01-000-801 |
| Removal of the Synthetic Vision Computer (SVC) | AMM 34-34-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset SVS (CB2-A7) circuit breakers.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of the ARINC 429 data bus R-IRS-4 from SVC connector A230AP1 to Junction Box 2 connector JB2EP1 or respective Test Points. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace SVC.
- If system checks passes, do close out.
- If fault remains, continue with next step.
- Replace Junction Box 2.
- Do close out.