Message Overview:
Message Description:
A disagreement has been detected between the position feedback from the BLEED VALVE 1 to the Data Concentrator Unit and the Left PBA selection feedback to the Data Concentrator Unit.
Possible Causes:
- Bleed Valve 1
- Data Concentrator Unit (DCU) (A14)
- Left PBA selection feedback to the Data Concentrator Unit (DCU)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 5
- Comp Id = V03
- {Term Definitions}
- DWDC1-9 1X 106 00 EXCT XXXX-XXXX XXXT-XXXX XXXX-XXXX 106A: 21;L BV OPEN
- DWDC1-8 1X 106 00 EXCT XXXX-XXXX XXXX-XTXX XXXX-XXXX 106A: 19;L BLEED PBA SEL OFF
Quick Links:
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Removal of the Bleed Check Valve | AMM 36-11-09-000-801 |
| Installation of the Bleed Check Valve | AMM 36-11-09-400-801 |
| Removal of the Cross-Bleed Valve | AMM 36-11-15-000-801 |
| Installation of the Cross-Bleed Valve | AMM 36-11-15-400-801 |
| Deactivation of the Cross-Bleed Valve | AMM 36-11-15-040-801 |
| Activation of the Cross-Bleed Valve | AMM 36-11-15-440-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Do a wiring check.