Message Overview:
Message Description:
A disagreement has been detected between the position feedback from the HIGH PRESSURE VALVE 1 to the Data Concentrator Unit and the WING PBA selection feedback to the Data Concentrator Unit.
Possible Causes:
- L High Pressure Valve (HPV1) (V5)
- L High Pressure Sensor (HPS) (MT19)
- WING Push Button Annunciator (PBA)
- Data Concentrator Unit (DCU) (A14)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 5
- {Term Definitions}
- DWDC2-3 2X 105 00 EXCT XXXT-XXXX XXXX-XXXX XXXX-XXXX 105B: 29;L HPV OPEN
- DWDC2-16 2X 111 00 EXCT XXXX-XXXX XXXX-XXXX XXTX-XXXX 111B: 14;WING A/I SELECTED OFF B
Quick Links:
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Leak Test of the High-Pressure Bleed-Air System | AMM 36-15-00-790-801 |
| Removal of the High Pressure Valve | AMM 36-15-01-000-801 |
| Installation of the High Pressure Valve | AMM 36-15-01-400-801 |
| Removal of the High Pressure Sensors | AMM 36-15-03-000-801 |
| Installation of the High Pressure Sensors | AMM 36-15-03-400-801 |
| Operational Test of the Maintenance Diagnostic System | AMM 45-45-00-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do a wiring check.