Message Overview:
Message Description:
The HIGH PRESSURE VALVE 2 is detected failed in open position.
Possible Causes:
- High Pressure Valve 2 (HPV) (V6)
- Position Switch
- Integrated Air System Controller 2 (IASC) (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Fault Confirmation Procedure:
- Message# = 2
- {Term Definitions}
- IAS2A-74 XX 353 11 EXCT XXXX-XXXX XXXX-XTXX XXXX-XXXX 353B: 19; HI PRESS VALVE 2 FAIL /
Quick Links:
| Removal of the Data Concentrator Unit (DCU) | AMM 31-41-01-000-802 |
| Installation of the Data Concentrator Unit (DCU) | AMM 31-41-01-400-802 |
| Leak Test of the High-Pressure Bleed-Air System | AMM 36-15-00-790-801 |
| Removal of the High Pressure Valve | AMM 36-15-01-000-801 |
| Installation of the High Pressure Valve | AMM 36-15-01-400-801 |
| Removal of the High Pressure Sensors | AMM 36-15-03-000-801 |
| Installation of the High Pressure Sensors | AMM 36-15-03-400-801 |
| Operational Test of the Maintenance Diagnostic System | AMM 45-45-00-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check valve or position switch or wiring between the valve, and the IASC #2.