background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/07/21

Message Overview:

Message Name:

NO OUTPUT BUS TO DBU

Message Code:

B3-481661

Associated CAS:

None

Reporting LRU: MDC
System Description: 31-45-00
Schematic Diagram: 31-45-00
Wiring Diagram: 31-45-01

Message Description:

DBU is reporting a missing MDC bus input.

Possible Causes:

  • Maintenance Diagnostic Computer (MDC) (A4-MDC)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Component Location AMM 45-45-00-992-801
Operational Test of the Maintenance Diagnostic System AMM 45-45-00-710-801
Load the Maintenance Diagnostic Computer (MDC) Checklists AMM 45-45-01-970-801
Data Download from the Maintenance Diagnostic Computer (MDC) AMM 45-45-01-970-802
Load the Maintenance Diagnostic Tables (MDT) to the Maintenance Diagnostic Computer (MDC) AMM 45-45-01-970-803
Load the Test and Rigging Files to the Maintenance Diagnostic Computer (MDC) AMM 45-45-01-970-804
Removal of the Maintenance Diagnostic Computer (MDC) AMM 45-45-01-000-801
Installation of the Maintenance Diagnostic Computer (MDC) AMM 45-45-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Reset R IAPS Circuit Breaker CB2-B6 and DATA LOADER Circuit Breaker CB3-D1. Is the fault message still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  2. Do wiring check between IAPS Card Cage (A4) and DBU (A191) for the following wires:

    From To Result
    Conn. A4P103 - 44 Conn. A191P1 - f
    Conn. A4P103 - 45 Conn. A191P1 - w

    1. If check is satisfactory, continue with next step.
    2. If check is not satisfactory, repair defective wiring.

  3. Replace DBU (A191). Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  4. Replace MDC. Is the fault message still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  5. Replace IAPS Card Cage (A4).
  6. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.