background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/07/21

Message Overview:

Message Name:

APPLICATION FAULT

Message Code:

B3-471458

Associated CAS:

None

Reporting LRU: FSU 1
System Description: 46-00-00
Schematic Diagram: 46-21-00
Wiring Diagram: 46-21-01

Message Description:

Left File Server Unit (FSU) software detected a fatal fault relating to the software installed.

Possible Causes:

  • File Server Unit (FSU) Software Application (FSA-5000)
  • Left File Server Unit (FSU 1) (A221)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure: Check FSA-5000 software version installed on the FSUs. Refer to Rockwell Collins Service Information Letter IFIS-5000 SIL 1-03.

Quick Links:

Load the FSA-5000 Application Software to the File Server Unit (FSU) AMM 46-21-01-970-801
Removal of the File Server Unit (FSU) AMM 46-21-01-000-801
Installation of the File Server Unit (FSU) AMM 46-21-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Load the FSA-5000 Application Software to the Left File Server Unit (FSU 1).
  2. Swap Left File Server Unit (A221) with Right File Server Unit (A222) and reload FSA-5000 Application Software if necessary.
  3. Do close out.

NOTE:

  1. The FSA-5000 must be installed prior to enabling applications.
  2. The FSA-5000 must be installed prior to installing the databases.

Rockwell Collins References:

  1. Encrypted Application Key Enabling, refer to the IFIS Installation manual (Rockwell Collins CPN 523-0780854) for installation specifics.
  2. Subscription Database Installation, refer to the Field Loadable Software installation Manual (Rockwell Collins CPN 523-0806267).
  3. Rockwell Collins IFIS-5000 SIL 1-03 for the procedures of FSU software loading and subscription database installation.
  4. Pro Line 21 Continuum IFIS-5000 Installation Manual (Rockwell Collins CPN 523-0780854).
  5. Field Loadable Software Installation Manual (Rockwell Collins CPN 523-0806267).
  6. CPAS-3000 Data Loader Operator's Guide (Rockwell Collins CPN 523-0790386).
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.