Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/07/21

Message Overview:

Message Name:

CONFIG CONNECTION LOST

Message Code:

B3-478744

Associated CAS:

None

Reporting LRU: FSU 1 CHARTS
System Description: 46-00-00
Schematic Diagram: 46-21-00
Wiring Diagram: 46-21-01

Message Description:

File Server Unit (FSU) 1 has reported an internal communication fault.

Possible Causes:

  • File Server Unit (FSU) Software Application (FSA-5000)
  • Left File Server Unit 1 (FSU 1) (A221)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Fault Confirmation Procedure: Check FSA-5000 software version installed on the FSUs. Refer to Rockwell Collins Service Information Letter IFIS-5000 SIL 1-03.

Quick Links:

Load the FSA-5000 Application Software to the File Server Unit (FSU) AMM 46-21-01-970-801
Removal of the File Server Unit (FSU) AMM 46-21-01-000-801
Installation of the File Server Unit (FSU) AMM 46-21-01-400-801

Troubleshooting Recommendations:

  1. Load the FSA-5000 Application Software to the Left File Server Unit (FSU 1).
  2. Swap Left File Server Unit (A221) with Right File Server Unit (A222) and reload FSA-5000 Application Software if necessary.
  3. Do close out.

NOTE:

  1. The FSA-5000 must be installed prior to enabling applications.
  2. The FSA-5000 must be installed prior to installing the databases.

Rockwell Collins References:

  1. Encrypted Application Key Enabling, refer to the IFIS Installation manual (Rockwell Collins CPN 523-0780854) for installation specifics.
  2. Subscription Database Installation, refer to the Field Loadable Software installation Manual (Rockwell Collins CPN 523-0806267).
  3. Rockwell CollinsIFIS-5000 SIL 1-03 for the procedures of FSU software loading and subscription database installation.
  4. Pro Line 21 Continuum IFIS-5000 Installation Manual (Rockwell Collins CPN 523-0780854).
  5. Field Loadable Software Installation Manual (Rockwell Collins CPN 523-0806267).
  6. CPAS-3000 Data Loader Operator's Guide (Rockwell Collins CPN 523-0790386).
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.