Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/08/21

Message Overview:

Message Name:

APPLICATION FAULT

Message Code:

B3-478807

Associated CAS:

None

Reporting LRU: FSU 2 MAPS
System Description: 46-00-00
Schematic Diagram: 46-21-00
Wiring Diagram: 46-21-03
46-21-05

Message Description:

File Server Unit (FSU) 2 software detected a software fault. This would include faults relating to a mis-configuration of the File Server Unit (FSU) Software Application (FSA) software. Reload FSU Software Application (FSA-5000).

Possible Causes:

  • File Server Unit (FSU) Software Application (FSA) (FSA-5000)
  • File Server Unit 2 (FSU 2) (A222)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-34-0189- Pro Line 21 Advanced Avionics Nuisance Messages and FMS-6200 Issues (20501 - 20999)

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Operational Test of the Single Integrated Flight Information System (IFIS) AMM 46-21-00-710-801
Operational Test of the Dual Integrated Flight Information System (IFIS) AMM 46-21-00-710-803
Load the FSA-5000 Application Software to the File Server Unit (FSU) AMM 46-21-01-970-801
Removal of the File Server Unit (FSU) AMM 46-21-01-000-801
Installation of the File Server Unit (FSU) AMM 46-21-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

The FSA-5000 is software that is loaded on the FSU-5010 and includes three feature options: The display of electronic charts, enhanced map overlays, and graphical weather.

  • FSA-5000 FSU Application Software
    (CPN 810-0001-002/003/004/005/006/008/009/100/104/105/106/108/109)
  • The new FSA version, CPN 810-0001-009, improves the operation of the OVL-5000
    The new FSA version, CPN 810-0001-109, improves the operation of the GWX-300X NEXRAD Map Overlay and improves the operation of the OVL-5000

  1. Check the part number of the FSA and software version for the FSU 2.

    1. Refer to tables below for Software Versions. For verification of software loaded on the aircraft, verify that the FSA part number and CRC on the Multifunction Display match those in the compatibility chart.

FSA-5000 INSTALLATION AND BENCH VERIFICATION DATA
FSA-5000 COL_NODE TARGET
FSU NODE LOADSET
COL_FSU TARGET
FSU CPR LOADSET
CPN CRC CPN CRC
810-0001-002 815-5596-002 8151DCFC 810-0001-002 AFF014F1
810-0001-003 815-5596-002 8151DCFC 810-0001-003 2BB1AE59
810-0001-100 815-5596-101 54E274B2 810-0001-100 10889FD8
810-0001-004 815-5596-002 8151DCFC 810-0001-004 DED14ADF
810-0001-104 815-5596-101 54E274B2 810-0001-104 8CEF1F9A
810-0001-005 815-5596-003 CB8333B7 810-0001-005 73B2184B
810-0001-105 815-5596-101 54E274B2 810-0001-105 765E1E2F
810-0001-006 815-5596-003 CB8333B7 810-0001-006 42DAF90F
810-0001-106 815-5596-102 17966CDC 810-0001-106 0E568A9B
810-0001-008 815-5596-005 2D20F306 810-0001-008 5C9B91DC
810-0001-108 815-5596-104 CCEAFB31 810-0001-108 C0B855B3
810-0001-009 815-5596-006 EA41DDB0 810-0001-009 9AB8A460
810-0001-109 815-5596-105 B5FFE384 810-0001-109 88C85366
FSU-5010 / FSA-5000 COMPATIBILITY
FSA-5000 FSU-5010 (CPN 822-1543-XXX)
101
810-0001-002 *
810-0001-003 *
810-0001-100 *
810-0001-004 *
810-0001-104 *
810-0001-005 *
810-0001-105 *
810-0001-006 *
810-0001-106 *
810-0001-008 *
810-0001-108 *
810-0001-009 *
810-0001-109 *
FSA-5000 / OVL-5000 COMPATIBILITY
OVL-5000 FSA-5000 (CPN 810-0001-XXX)
002 003 100 004 104 005 105 006 106 008 108 009 109
810-0003-001 * * * * * * * * * * * * *
FSA-5000 / ECH-5000 COMPATIBILITY
ECH-5000 FSA-5000 (CPN 810-0001-XXX)
002 003 100 004 104 005 105 006 106 008 108 009 109
810-0002-001 * * * * * * * * * * * * *
FSA-5000 / GWX-5000 COMPATIBILITY
GWX-5000 FSA-5000 (CPN 810-0001-XXX)
002 003 100 004 104 005 105 006 106 008 108 009 109
810-0004-001 * * * * * *
FSA-5000 / GWX-3000 COMPATIBILITY
GWX-3000 FSA-5000 (CPN 810-0001-XXX)
002 003 100 004 104 005 105 006 106 008 108 009 109
810-0007-001 * * * * * *
FSA-5000 / GWX-3001 COMPATIBILITY
GWX-3001 FSA-5000 (CPN 810-0001-XXX)
002 003 100 004 104 005 105 006 106 008 108 009 109
810-0058-001 * *

NOTE: The marking for the FSA-5000 is shown on the CD Rom face. The FSA-5000 part number, build date and cyclical redundancy check number for the CPR load set are also available on the avionics display. See the Field Loadable Software Installation Manual (CPN 523-0806267) for procedure to display the FSA part number information.

  1. If the part number or software version is not compatible, install the correct software to FSU 1, refer to the FSU-5010 section of the Field Loadable Software Installation Manual (CPN 523-0806267) for installation instructions.

    NOTE:

    1. The FSA-5000 must be installed prior to enabling applications.
    2. The FSA-5000 must be installed prior to installing the databases.

      Refer to the IFIS Installation manual (CPN 523-0780854) for installation specifics.

  2. If the message can not be cleared after the above actions, swap the FSU 2 with the FSU 1 (A221).
  3. If step 3 does not help, replace the FSU No. 2.

References:

  1. Encrypted Application Key Enabling, refer to the IFIS Installation manual (Rockwell Collins CPN 523-0780854) for installation specifics.
  2. Subscription Database Installation, refer to the Field Loadable Software installation Manual (Rockwell Collins CPN 523-0806267).
  3. Rockwell Collins SIL 1-03 for the procedures of FSU software loading and subscription database installation.
  4. Pro Line 21 Continuum IFIS-5000 Installation Manual (Rockwell Collins CPN 523-0780854).
  5. Field Loadable Software Installation Manual (Rockwell Collins CPN 523-0806267).
  6. CPAS-3000 Data Loader Operator's Guide (Rockwell Collins CPN 523-0790386).
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.