Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/08/21

Message Overview:

Message Name:

OPN/SHRT TORQUE MOTOR
(Service Message)

Message Code:

B3-006327

Associated CAS:

None

Reporting LRU: APU FUEL CTRL
System Description: 49-00-00
Schematic Diagram: 49-61-00
Wiring Diagram: 49-61-01 Sh 1
49-61-01 Sh 2

Message Description:

Open or short circuit of the Fuel Control Unit Torque Motor.

Possible Causes:

  • Fuel Control Torque Motor (A175)
  • Auxiliary Power Unit (APU) Electronic Control Unit (ECU) (A39)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Fuel Control Unit AMM 49-31-01-000-801
Installation of the Fuel Control Unit AMM 49-31-01-400-801
Removal of the Auxiliary Power Unit (APU) Electronic Control Unit (ECU) AMM 49-61-01-000-801
Installation of the Auxiliary Power Unit (APU) Electronic Control Unit (ECU) AMM 49-61-01-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Do wiring check from APU ECU (A39) to the Fuel Control Unit (A175) for the following wires:

    From To Result
    Conn. A39BP1-5C Conn. A175P1-1
    Conn. A39BP1-5D Conn. A175P1-3

    1. If the check is satisfactory, continue with next step.
    2. If the check is not satisfactory, repair defective wiring.

  2. Replace Fuel Control Unit (A175). Is the fault message still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  3. Replace APU ECU (A39).
  4. Do close out.