Message Overview:
Message Description:
Proximity Sensor Electronic Unit (PSEU) detects a marginal or out of rig condition to the Proximity Sensor PX49, Right-hand Over-Wing Emergency Door Locked. Sensor is healthy, but requires proper rigging.
Possible Causes:
- Right Overwing Emergency Door Closed Proximity Sensor (PX49)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Functional Test of the Proximity-Sensor Electronic Unit (PSEU) | AMM 32-61-09-720-801 |
| Removal of the Over-Wing Emergency-Exit Proximity-Sensor | AMM 52-71-21-000-801 |
| Installation of the Over-Wing Emergency-Exit Proximity-Sensor | AMM 52-71-21-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do the mechanical adjustment (rigging) for PX49 (Installation of the Over-Wing Emergency-Exit Proximity Sensor).
- Do the Built-In-Test of the Door Proximity Sensors.
- If test is good, do close out.
- If fault remains, continue with next step.
- Reset the PSEU circuit breakers CB1-C13, CB1-C14, CB2-C13, CB2-C14.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PX49 sensor.
- If system checks are good, do close out.
- If fault remains, go to step 1.