04/26/21
Message Overview:
Message Description:
The FGP/Servos CB1-B7 or CB2-B7 is tripping when AP is engaged.
Possible Causes:
- Aileron Servo (A126)
- Elevator Servo (A125)
- Flight Guidance Panel (FGP) (PL9)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Flight Guidance Panel (FGP) | AMM 22-11-05-000-801 |
| Installation of the Flight Guidance Panel (FGP) | AMM 22-11-05-400-801 |
| Removal of the Aileron Servo Mount | AMM 22-11-09-000-801 |
| Installation of the Aileron Servo Mount | AMM 22-11-09-400-801 |
| Removal of the Elevator Servo Mount | AMM 22-11-13-000-801 |
| Installation of the Elevator Servo Mount | AMM 22-11-13-400-801 |
| Removal of the Aileron Servo | AMM 22-11-17-000-801 |
| Installation of the Aileron Servo | AMM 22-11-17-400-801 |
| Removal of the Elevator Servo | AMM 22-11-21-000-801 |
| Installation of the Elevator Servo | AMM 22-11-21-400-801 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check to see if the Aileron or Elevator Servo is shorted by removing the FGP and accessing connectors PL9P1 and PL9P2.
- Perform continuity check on following wires:
Servo Clutch From: To: Expected
Results:Actual
Results:Elevator Servo Clutch (A125 pin M) PL9P1 pin k PL9P1 pin P Chassis GND ≈ 36Ω Aileron Servo Clutch (A126 pin E) PL9P2 pin k PL9P2 pin P Chassis GND ≈ 36Ω - If continuity check fails, replace the corresponding failed Servo.
- Reset CB1-B7 if Elevator Servo was replaced.
- Reset CB2-B7 if Aileron Servo was replaced.
- If continuity check fails, replace the corresponding failed Servo.
- Do close out.