Message Overview:
Message Description:
The amber 'IRS 1/IRS 2' caution flag indicates that the IRS reversion has been selected and the indicated IRS is providing data to both PFDs.
- The reversionary switching has selected one source for the IRS, there is no system redundancy
Possible Causes:
- Input/Output Concentrator (IOC) (A4-IOC)
- Inertial Reference Unit 1 (IRS 1) (A233)
- Inertial Reference Unit 2 (IRS 2) (A232)
- Data Bus Failure
- IRS source select switch on the Reversion Select Panel (PL27)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
| Operational Test of the Inertial Reference System (IRS) | AMM 34-45-00-710-801 |
| Removal of the Inertial Reference Unit (IRU) | AMM 34-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 34-45-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Set the IRS source reversion selection knob (PL27) to the NORM position. Is the indication still present?
- If YES, continue with next step.
- If NO, do close out.
- Perform a wiring check between the IRS source reversion selection knob (PL27) and the PFDs and MFDs.
- If wiring defects are found, repair defective wiring as required and do close out.
- If no defects are found, continue with next step.
- Perform a continuity check directly on IRS source select switch on the Reversion Select Panel. Repair/replace if required.
- Do close out.