Message Overview:
Message Description:
The APU starts up and then shuts down.
Possible Causes:
- Load Control Valve (LCV) (V8)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Load Control Valve | AMM 49-52-01-000-801 |
| Installation of the Load Control Valve | AMM 49-52-01-400-801 |
| Deactivation of the Load Control Valve | AMM 49-52-01-040-801 |
| Activation of the Load Control Valve | AMM 49-52-01-440-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Inspect the Load Control Valve (V8). Is it stuck open?
- If YES, free up the valve or replace it.
- If NO, call tech support.
- Do close out.